DX51D Galvanized Sheet in Medical Device Applications

Feb 05, 2026 Leave a message

Can DX51D Contact Patients or Medications

No. The galvanized layer may leach zinc ions, and the surface cannot achieve long-term sterility and stability. It is only suitable for peripheral components that come into indirect contact with patients or medications, such as equipment housings, frames, and mounting brackets.

Operating Temperature Range

The standard operating temperature range is minus 20 to 120 degrees C. Hot-dip galvanized layers are prone to embrittlement above 250 degrees C, making them unsuitable for high-temperature sterilization such as high-pressure steam or prolonged high-temperature operation. Medical devices with autoclave sterilization requirements must use alternative materials or coatings.

Selecting the Zinc Coating Weight

Select Z100 for dry indoor medical environments; Z180 for humid or frequent disinfection scenarios such as endoscopy centers and ICU equipment housings; and Z275 for outdoor or frequently cleaned equipment. Higher coatings extend the corrosion protection life in aggressive environments.

Standards Compliance

The material must comply with EN 10346 for galvanized steel sheet, and the medical device enclosure must meet IEC 60601-1 electrical safety, as well as RoHS and REACH environmental requirements. These standards govern material properties, safety, and restricted substances.

Biocompatibility Requirements

In its original state, DX51D does not meet biocompatibility requirements. If it must contact non-sterile human surfaces such as equipment handrails, a surface coating such as epoxy or polyurethane must be applied and it must pass the ISO 10993 skin irritation test.

Frequently Asked Questions

Q: Can DX51D be used for patient-contact parts?
No, the zinc layer may leach ions and cannot maintain sterility; it suits only indirect-contact peripheral components.

Q: What is the operating temperature range?
Minus 20 to 120 degrees C, with embrittlement above 250 degrees C, so it cannot be autoclaved.

Q: Which coating for ICU equipment housings?
Z180 for humid and frequent disinfection environments; Z100 for dry indoor use; Z275 for outdoor service.

Q: What standards apply to medical enclosures?
EN 10346 for the material, IEC 60601-1 for electrical safety, and RoHS and REACH for substances.

Q: Does DX51D meet biocompatibility?
Not in its original state; coated versions must pass the ISO 10993 skin irritation test for contact surfaces.

Q: Can galvanized sheet be sterilized?
Not by high-pressure steam, since the coating embrittles above 250 degrees C.