Pad Mounted Transformer
-
Three Phase Pad Mounted TransformersThe 3 phase pad-mounted transformer is a transformer designed with a fully enclosed structure. The layout of the heat sink that can directly dissipate heat to the outside makes Three phase...read more
-
Single Phase Pad Mounted TransformerPad-mounted transformers are made in power ratings from around 15 to around 5000 kVA and often include built-in fuses and switches. Primary power cables may be connected with elbow connectors,...read more
-
2000 KVA Pad Mounted Transformer2000 kVA pad-mounted transformer meets ANSI, CSA, NEMA, IEEE, DOE, etc standards. GNEE 2000 kVA pad-mount transformers meet DOE efficiency values with UL listed.2000kva pad-mounted transformers...read more
-
167 KVA Single Phase Pad Mounted TransformerGNEE 167 kVA pad mounted transformer meets/exceeds DOE 2016 efficiency ratings with UL/cUL listed. GNEE Transformer, a distinguished transformer supplier and manufacturer with a UL listing, offers...read more
-
Padmount Liquid Filled TransformersPadmount Liquid Filled Transformers For use on underground power distribution systems.read more
-
750 Kva Pad Mounted TransformerPrimary Voltage Ratings: 34.5-19.92/13.8-7.957/13.2-7.62/12.47-7.2 or othersread more
Secondary Voltage Ratings: 208GrdY/120;416GrdY/240,480GrdY/277,/600GrdY/347,220y/127,480V,415v,600v or others... -
2000 Kva Pad Mount TransformerThe 2000 kVA pad-mounted transformer complies with ANSI, CSA, NEMA, IEEE, DOE and other standards, meets DOE efficiency values and is UL certified.read more
-
750 Kva ~ 2500 Kva 3 Phase Pad-mounted Transformer750 kva ~ 2500 kva 3 phase pad-mounted transformer is a complete set of substation and distribution equipment that combines a combined transformer, a load switch and a protective fuse device for...read more
-
50 KVA Pad Mount Distribution TransformerGNEE’single and three-phase pad-mounted transformers are powerful, dependable, and designed with the environment in mind. With the ability to function indoors and outdoors, these transformers...read more
-
500 KVA Pad Mount Three-Phase Oil-Immersed Distribution T...Cooling Type:ONAN / KNANread more
Primary Voltage:2,400 – 46,000 V
Secondary Voltage:208Y/120 V to 14,400 V
Frequency:60 Hz -
Padmount TransformersThe safety of padmount transformers makes them an option for publicly accessible installations or any situation where underground wiring is preferred.read more
-
Three-phase Pad-mounted TransformerGNEE’s Cooper Power series three-phase pad-mounted transformers are compact power centers for utility, commercial or industrial applications, designed to withstand many types of environments.read more
Product Introduction
High Efficiency and Low Loss
High-quality materials and manufacturing: Utilizes premium silicon steel sheets (such as oriented silicon steel) and advanced winding technologies (e.g., foil winding or helical winding) to reduce no-load losses (iron loss) and load losses (copper loss).
Energy-Saving Design
Designed to comply with international energy efficiency standards.
The efficiency of certain models can exceed 99%, significantly reducing long-term operating costs.


Adaptability to Complex Power Grids
Wide voltage regulation: Supports on-load tap changers (OLTC) or no-load voltage regulation to accommodate a broader range of voltage fluctuations.
Harmonic suppression: Special winding designs (such as the Dyn11 connection group) are used to suppress third harmonics, ensuring compatibility with renewable energy sources like photovoltaics and wind power.
Short-circuit endurance: Short-circuit testing and optimized impedance design help minimize the impact of fault currents.
Customization and Global Applicability
Flexible design options: Customizable capacities (from 10 kVA to 1000 MVA), voltage levels (up to ±1100 kV ultra-high voltage), and special features (e.g., salt spray resistance, explosion-proof protection) can be tailored to meet customer requirements.
|
Tachnical Data for Three Phase Pad Mounted Transformer |
||||||
|
Rated Power (KVA) |
Loss (W) |
Dimension(mm) |
||||
|
No-load Loss (W) |
On-load Loss (W) |
W |
D |
H |
Weight(kg) |
|
|
75KVA |
180 |
1250 |
1390 |
910 |
1430 |
645 |
|
150KVA |
280 |
2200 |
1510 |
980 |
1530 |
989 |
|
300KVA |
480 |
3650 |
1660 |
1080 |
1680 |
1415 |
|
500KVA |
680 |
5100 |
1810 |
1160 |
1790 |
1905 |
|
750KVA |
980 |
7500 |
2030 |
1300 |
2030 |
2755 |
|
1000KVA |
1150 |
10300 |
1651 |
1549 |
1854 |
3235 |
|
1500KVA |
1640 |
14500 |
2210 |
1470 |
2150 |
5835 |
|
2000KVA |
2160 |
20645 |
2380 |
1600 |
2220 |
6430 |
|
2500KVA |
2680 |
27786 |
3070 |
1650 |
2330 |
8865 |
|
3000KVA |
3300 |
30300 |
3260 |
1850 |
2460 |
11300 |
|
3750KVA |
4125 |
37875 |
4080 |
2060 |
2680 |
14400 |
1. Designed by patented technology and software with premium performance.
2. Core is made of high quality cold-rolled grain-oriented silicon steel sheet which produced in step-lap technology.
3. Winding is using high strength enameled wire or paper-insulated wire or copper belt, which offers uniform distribution of ampere-turns, reasonable insulation structure with high ability to withstand short-circuit.
4. Oil tank is corrugated type with high corrosion resistance. Tank surface pre-treatment liquid and coating powder adopts international top brands. The tank is degreasing, pickling, phosphorated, electrophoresis by automatic production lines, then power spray coating and heat-solidify.
5. The active part applies core free-hanging structure. The gasket is made of high-quality acrylate rubber which can inhibit ageing caused by sun and heat.

Main Components
Tank
The outer shell that houses all the internal components.
Core
Typically made of laminated steel sheets.
Windings
Primary Winding and Secondary Winding.
Insulation
To prevent electrical conductivity between windings and the core, and turns of the windings.
Radiators/Heat Exchangers
To facilitate heat dissipation in oil-filled transformers.
Bushing
Maintain electrical isolation.
Tap Changer
Maintain voltage stability despite fluctuations in load or input voltage.
Breather
Regulate the intake of air when the oil level expands and contracts due to temperature changes for oil transformer.
Mounting Hardware
Bolts, brackets, and other hardware used to secure the transformer to its concrete pad.

1. Ambient temperature: Maximum +40ºC, Minimum -40ºC
2. Altitude: les Lehan 1000 meters.
3. Seismic level: less than 3m/s2 at horizontal direction and less than 1.5m/s2 at vertical direction.
4. Installation environment: No obvious and heavy pollution, no explosive and corrosive gas and dust, with good air ventilation and no severe vibration and shock.
(Note: If the application environment is different from the above standard conditions, please contact for customized designs.)
-Measurement of winding resistance
-Measurement of voltage ratio and check of phase displacement
-Measurement of short-circuit impedance and loss
-Measurement of no-load loss and current
-Dielectric routine tests
-Tests on on-load tap-changers, where appropriate
-Leak testing with pressure for liquid-immersed transformers(tightness test)
-Tightness tests and pressure tests for tanks for gas-filled transformers
-Check of the ratio and polarity of built-in current transformers
-Check of core and frame insulation for liquid immersed transformers with core or frame insulation

Type test
Temperature-rise type test
Dielectric type tests
Determination of sound level for each method of cooling for which a guaranteed sound level is specified
Measurement of the power taken by the fan and liquid pump motors
Measurement of no-load loss and current at 90% and 110% of rated voltage

Special test
-Dielectric special tests
-Winding hot-spot temperature-rise measurement
-Determination of capacitances windings-to-earth, and between windings
-Measurement of dissipation factor(tanδ) of the insulation system capacitances
-Determination of transient voltage transfer characteristics
-Measurement of zero-sequence impedance(s) on three-phase transformers
-Short-circuit withstand test
-Measurement of d.c. insulation resistance each winding to earth and between windings
-Vacuum deflection test on liquid immersed transformers
-Pressure deflection test on liquid immersed transformers
-Vacuum tightness test on site on liquid immersed transformers
Certificates

FAQ
We're professional pad mounted transformer manufacturers and suppliers in China, specialized in providing high quality customized service. We warmly welcome you to buy cheap pad mounted transformer for sale here and get free sample from our factory. For price consultation, contact us.