Galvanized Steel Tape for Armoured Power and Communication Cables

Oct 29, 2025 Leave a message

Galvanized steel tape, also known as armoured cable tape, is a narrow strip of low-carbon steel carrying a hot-dip zinc coating and wound around cable cores to provide mechanical protection. The zinc layer prevents rust, so tape can be buried underground, drawn into ducts or laid under water without losing the protection it is fitted to provide.

What Galvanized Steel Tape Does in a Cable

Power and communication cables are protected by one or two helical layers of steel tape applied over the inner sheath, usually with an overlap and often in opposite directions so that the layers lock against each other. The armour resists impact and crushing during installation, protects the cable against rodents and digging damage, and adds a radial barrier that limits the spread of moisture along the cable. Because the tape is metallic and continuous, the armour can also be connected to earth, and cable makers select tape thickness and width to match the cable diameter and the installation conditions the cable is designed for.

Why the Tape Is Galvanized

Zinc protects steel in two ways: it seals the surface against the atmosphere, and where the coating is scratched or cut it corrodes in preference to the steel beneath, which keeps small damaged areas protected. Cable tape carries coating masses in the region of 80 g/m2 to 140 g/m2 on the strip, which is enough for long service underground and in wet ducts. The tape must also bend tightly around the cable core without cracking the coating, so coating adhesion and base steel ductility matter as much as tensile strength: this is why a minimum elongation is always specified together with the tensile range.

Typical Specifications and Size Range

Thickness Thickness tolerance Width Width tolerance Tensile strength Zinc coating Minimum elongation in 250 mm
0.20 mm +/- 0.02 mm 20 mm, 30 mm +/- 0.1 mm 27.6 kg/mm2 to 48.19 kg/mm2 (about 270 MPa to 473 MPa) 80 g/m2 to 140 g/m2 10%
0.50 mm +/- 0.05 mm 30 mm, 40 mm, 50 mm, 60 mm +/- 0.1 mm to +/- 0.2 mm 27.6 kg/mm2 to 48.19 kg/mm2 (about 270 MPa to 473 MPa) 80 g/m2 to 140 g/m2 10%
0.80 mm +/- 0.08 mm 50 mm, 60 mm +/- 0.2 mm 27.6 kg/mm2 to 48.19 kg/mm2 (about 270 MPa to 473 MPa) 80 g/m2 to 140 g/m2 10%

Tensile strength is still quoted in the trade in kilograms per square millimetre, and the equivalent in megapascals is given alongside for comparison with modern specifications. Widths up to a maximum of 605 mm can be supplied, which allows a cable maker to slit the exact width required in house. Because the tape is slit from continuously coated strip, width tolerance and edge quality are set at the slitting stage and should be agreed before the order is placed rather than left to the finished coil.

Standards and Ordering Points

Galvanized steel tape is manufactured to the requirements of recognised standards such as those issued by ASTM, IEC and ICEA, and to individual customer specifications where a cable design calls for something different. Where the tape is slit from continuously hot-dip coated steel strip, the general requirements for the base sheet are commonly taken from ASTM A924/A924M, and the zinc coating is verified as mass per unit area rather than judged by appearance. An enquiry should always state thickness and thickness tolerance, width and width tolerance, tensile range, minimum elongation, coating mass, edge condition and burr limits, coil inner diameter, coil weight and whether a material certificate is required.

Supply Form, Packing and Handling

Tape is supplied in coils wrapped in waterproof packing so that the zinc surface reaches the cable plant dry and free from white rust. Coils are normally interleaved or paper wrapped, banded and identified by grade, coil number and dimensions. Stores should keep them off the ground in a dry, ventilated place. During cable manufacture the main handling risks are burrs and edge damage on the slitting line, which can mark the inner sheath, and surface contamination by oil or grease, which prevents the armour from bonding where the design requires it.

Frequently Asked Questions

Q: What is galvanized steel tape used for?
Its main use is as armour tape in power, communication and fibre optic cables, where one or two helical layers give mechanical protection, a moisture barrier and an earthed metallic screen against electrical and physical damage.

Q: Why is the tape galvanized instead of bare or painted?
Zinc both seals the surface and protects it sacrificially at scratches and cut edges, so bare steel would rust quickly underground or in wet ducts, while paint cannot provide the same self-repairing protection.

Q: What thicknesses and widths are available?
Common thicknesses are 0.20 mm, 0.50 mm and 0.80 mm with tolerances from +/- 0.02 mm to +/- 0.08 mm, in widths from 20 mm to 60 mm as standard and up to a maximum of 605 mm.

Q: What tensile strength and elongation should be specified?
The usual range is 27.6 kg/mm2 to 48.19 kg/mm2, equivalent to about 270 MPa to 473 MPa, with a minimum elongation of 10% measured over a 250 mm gauge length so the tape wraps without cracking.

Q: What zinc coating mass does the tape carry?
Coating masses of 80 g/m2 to 140 g/m2 are typical, and being a hot-dip coating it covers both surfaces of the strip to protect the tape in buried, ducted and submerged installations.

Q: How is the tape packed and supplied?
It is supplied in coils with waterproof wrapping, interleaved or paper wrapped and banded with the grade, coil number and dimensions marked, so the zinc surface arrives clean and dry.