How to Choose Base Metal Based on Applications?

 

Send Us Your Requirements:

Size: the thickness, width, zinc coating thickness, coil weight?
Material and Grade: Hot rolled steel or cold rolled steel? And with spangles or not?
Application: What is the purpose of the coil?
Quantity: How many tons do you need? The MOQ is 25 tons.
Delivery: When is it needed and where is your port?
If you have special requirements, please let us know.

 

Uses Code Yield Strength (MPa) Tensile Strength (MPa) Elongation at Break A80mm%
General uses DC51D+Z 140 ~ 300 270 ~500 ≧22
Stamping use DC52D+Z 140 ~ 260 270 ~ 420 ≧26
Deep drawing use DC53D+Z 140 ~ 220 270 ~ 380 ≧30
Extra deep drawing DC54D+Z 120 ~ 200 260 ~ 350 ≧36
Ultra-deep drawing DC56D+Z 120 ~ 180 260 ~ 350 ≧39
Structural uses S220GD+Z
S250GD+Z
S280GD+Z
S320GD+Z
S350GD+Z
S550GD+Z
220
250
280
320
350
550
300
330
360
390
420
550
≧20
≧19
≧18
≧17
≧16
/

 

Material Chinese Code Japanese Code European Code
Commercial Use DX51D+Z/DC51D+Z (CR) SGCC DX51D+Z
Drawing Quality DX52D+Z/DC52D+Z SGCD1 DX52D+Z
Deep Drawing Quality DX53D+Z/DC53D+Z/DX54D+Z/DC54D+Z SGCD2/SGCD3 DX53D+Z/DX54D+Z
Structural Use S220/250/280/320/350/550GD+Z SGC340/400/440/490/570 S220/250/280/320/350GD+Z
Commercial Use DX51D+Z/DD51D+Z (HR) SGHC DX51D+Z

 

In general, Z stands for pure zinc coating and ZF refers to zinc-iron alloy coating. The number represents the thickness of the zinc layer. For example, Z120 or Z12 means the weight of zinc coating (double-sided) per square meter is 120 grams. While the zinc coating of the single side will be 60 g/㎡. Below is the recommended zinc layer thickness for different use environments.

 

Use Environment Recommended Zinc layer Thickness
Indoor uses Z10 or Z12 (100 g/㎡or 120 g/㎡)
Suburban area Z20 and painted (200 g/㎡)
Urban or industrial area Z27 (270 g/㎡) or G90 (American Standard) and painted
Coastal area Thicker than Z27 (270 g/㎡) or G90 (American Standard) and painted
Stamping or deep drawing applications Thinner than Z27 (270 g/㎡) or G90 (American Standard) to avoid coating peeling off after stamping

 