Welded steel grating, also called metal open bar grating, is produced by assembling a series of load-bearing flat bars and cross bars at fixed pitches and then forge-welding the intersections. The result is an open, rigid panel that carries heavy foot traffic and equipment loads while allowing light, air, water, oil and debris to pass straight through.
The combination of an anti-slip walking surface, high load bearing capacity, free drainage, corrosion resistance after galvanizing and simple installation is why the product is specified for factory walkways, stair treads, platforms, trenches, bridge decks, parking structures, viewing platforms, parks and gardens.
Construction and Material Options
Two element families make up every welded grating panel.
Bearing bars: the load-carrying flat bars, supplied either with a plain (smooth) top edge or a serrated (toothed) top edge. Bearing bar depth and thickness control the load rating and the stiffness of the panel.
Cross bars: round or twisted square bars welded across the bearing bars to hold the pitch, distribute concentrated loads and prevent sideways slip of footwear. Common diameters are 6 mm and 10 mm.
Standard bearing bar pitches are 30 mm, 40 mm and 60 mm, and cross bar pitches are 50 mm and 100 mm. A tighter bearing bar pitch raises the load capacity and makes the surface more comfortable for trolley wheels, while a wider pitch reduces weight and improves drainage.
| Item | Range | Effect |
|---|---|---|
| Base material | Low carbon structural steel Q235B or SS400; stainless steel where aggressive media are present | Sets strength and corrosion baseline |
| Bearing bar depth | 20 mm to 70 mm | Principal driver of load capacity |
| Bearing bar thickness | 3 mm to 5 mm | Secondary driver of load capacity and abrasion life |
| Cross bar diameter | 6 mm or 10 mm | Load distribution and slip resistance |
| Bearing bar pitch | 30 mm, 40 mm, 60 mm | Capacity, weight and drainage |
| Cross bar pitch | 50 mm or 100 mm | Stiffness and surface support |
| Surface treatment | Hot-dip galvanized, mill finish, painted or powder coated | Service life in the target environment |
| Surface type | Plain or serrated top edge | Slip resistance on ramps and wet areas |
Standard Specification Range
The designation system links the bearing bar size and the panel geometry, which allows the panel to be ordered and replaced without ambiguity. The table below lists the common welded grating series and their element dimensions.
| Item code | Bearing bar (mm) | Cross bar diameter (mm) | Bearing bar pitch (mm) | Cross bar pitch (mm) |
|---|---|---|---|---|
| SG-2036 | 20 x 3 | 6 | 30 | 100 |
| SG-2056 | 20 x 5 | 6 | 30 | 100 |
| SG-3036 | 30 x 3 | 6 | 30 | 100 |
| SG-3046 | 30 x 4 | 6 | 30 | 100 |
| SG-3056 | 30 x 5 | 6 | 30 | 100 |
| SG-3256 | 32 x 5 | 6 | 40 | 100 |
| SG-3556 | 35 x 5 | 6 | 40 | 100 |
| SG-4036 | 40 x 3 | 6 | 40 | 50 |
| SG-4056 | 40 x 5 | 6 | 40 | 50 |
| SG-45510 | 45 x 5 | 10 | 60 | 50 |
| SG-50510 | 50 x 5 | 10 | 60 | 50 |
| SG-60510 | 60 x 5 | 10 | 60 | 50 |
| SG-70510 | 70 x 5 | 10 | 60 | 50 |
Dimensioning, tolerances and the load tables themselves are normally taken from the steel grating product standard GB/T 4001.1, using the unified load and deflection tables in its annexes. Where a project is designed to an international specification, the metal bar grating design manual is used instead, and the two approaches should not be mixed on the same structure.
Load Bearing Capacity and Design Verification
Load capacity is not a single number. It depends on the span between supports, the bearing bar depth, the bearing bar pitch, the load case and the allowable deflection. Three checks govern a safe design:
Bending stress: the calculated stress in the bearing bars under the design load, for both uniformly distributed and concentrated patch loads, must stay below the allowable stress for the base material.
Deflection: most walkway and platform specifications limit deflection to between L/200 and L/400 of the clear span, with the stricter figure used where trolleys or fragile finishes are involved.
Span: the clear distance between supporting members is the single most influential input. Doubling the span with the same panel reduces capacity sharply, so spans should be confirmed before the panel series is chosen.
A concentrated patch load applied between the bearing bars is usually the governing case for a 30 mm pitch panel, while a 60 mm pitch panel is normally governed by deflection instead. Heavier duty is met by increasing bearing bar depth, reducing the bearing bar pitch, adding intermediate supports, or using a clamp-fixed and cross-braced arrangement.
Anti-Slip Surfaces and Corrosion Protection
Slip resistance is built into the panel in one of two ways. A serrated bearing bar has a toothed top edge that bites into footwear and provides grip even when the surface is wet or oily; it is standard practice on ramps, stair treads, offshore walkways and any location where spillage is expected. A plain bearing bar is smoother, easier to clean and more comfortable for bare hands, and it is preferred for platforms that are regularly hosed down.
| Finish | Typical application | Service note |
|---|---|---|
| Hot-dip galvanized to EN ISO 1461 or ASTM A123 | Outdoor platforms, bridges, parking structures | Average coating thickness of about 70 to 85 micrometers on members 3 mm and thicker |
| Mill finish | Indoor, dry, painted later on site | Lowest cost, no corrosion allowance |
| Painted or powder coated | Architectural and interior projects | Colour matching; touch-up required at cut edges |
Because the panel is open, moisture drains away and dust does not accumulate, which is why corrosion damage on galvanized grating is usually confined to cut edges and welds that were not re-protected during fabrication.
Applications, Fixing and Maintenance
Size panels to suit the supporting steelwork so that bearing bars span in the strong direction and never run parallel to the main supports.
Fix with saddle clips, bolted clamps or welded cleats. Removable fixing is preferred where panels cover trenches, pumps or valves.
Keep a minimum bearing of about 25 mm on each support so that the panel cannot rock under traffic.
Butt adjacent panels with a bearing bar at the joint or cover the joint with a nosing bar to avoid a trip edge.
Cut edges of galvanized panels require a zinc-rich repair coating to restore corrosion protection.
Inspection is visual and simple: check for loose clips, deformation of bearing bars, blocked drainage gaps and white rust on galvanized faces.
Typical Applications
Typical duties include factory and workshop flooring, maintenance walkways alongside process lines, stair treads and landings, pallet and trolley traffic areas, drainage and cable trench covers, port and logistics yard platforms, bridge inspection walkways, and public viewing platforms in parks and gardens where an open, vandal-resistant surface is required.
Frequently Asked Questions
Q: What is the difference between welded steel grating and press-locked grating?
Welded grating is forge-welded at every intersection and can use heavier bearing bars for high load duties, while press-locked grating is assembled by forcing cross bars through slots and is generally lighter, flatter and used for architectural and medium load panels.
Q: Which bearing bar size should be used for a walkway with a 1 metre span?
Capacity depends on the load case and deflection limit, so the load table should be checked for the exact span. As a rule, longer spans and heavier traffic push the selection toward deeper bearing bars and a tighter bearing bar pitch.
Q: When should serrated bearing bars be specified?
Use serrated bars wherever oil, water or dust can make the surface slippery, including ramps, stair treads and process areas. Plain bars are acceptable on dry, frequently cleaned platforms.
Q: Does hot-dip galvanizing reduce the load capacity of the grating?
No. The zinc coating does not change the structural behaviour of the bars, and the slight thickness increase is not counted as a structural contribution in design.
Q: How are grating panels fixed down?
Panels are held with saddle clips, bolted clamps or welded cleats at the supports. Removable fixings are used where the panel covers equipment that needs access for maintenance.
Q: Why does white rust appear on galvanized grating in storage?
White rust forms when moisture is trapped between stacked panels and cannot escape. Store panels on edge in a dry, ventilated place, keep them off the ground and separate stacked panels with spacers.