Q345 and Q355 Galvanized Steel: Strength, Corrosion Resistance and Dimensional Precision

Aug 28, 2025 Leave a message

Q345 has been one of the most familiar Chinese structural steel names for decades, valued for the combination of strength, weldability and economy. Since 2018 it has been formally superseded by Q355 under GB/T 1591, and buyers now order Q355B in most new projects. The same strength logic carries over into galvanized products: when the material must also resist corrosion, the steel is supplied as galvanized sheet or coil in the appropriate standard system. This article explains the grade transition, maps the galvanized grade systems, and reviews the applications that depend on strength, corrosion resistance and dimensional precision together.

From Q345 to Q355: The Grade Transition

Q345 was defined in the 2008 edition of GB/T 1591 as a low-alloy high-strength structural steel with a minimum yield strength of 345 MPa. The 2018 edition replaced the Q345 family with Q355, which guarantees a minimum yield strength of 355 MPa and, through a tighter carbon equivalent limit, improves weldability. The two designations describe essentially the same strength class, and existing drawings that call out Q345B are routinely satisfied by Q355B material, but the change should always be confirmed with the designer because the impact test grades and delivery conditions differ.

Galvanized Grade Systems for High-Strength Sheet and Coil

Standard Structural galvanized grades Yield strength level
GB/T 2518 (China) S280GD+Z to S550GD+Z 280-550 MPa
EN 10346 (Europe) S250GD+Z to S550GD+Z 250-550 MPa
JIS G 3302 (Japan) SGC340 to SGC570 340-570 MPa class
GB/T 1591 (structural plate) Q345B / Q355B 345 / 355 MPa min

For hot-dip galvanized coil, the practical high-strength choice in the Chinese market is the S350GD+Z or S450GD+Z grade of GB/T 2518, which matches the EN 10346 designations and combines a yield strength of 350 or 450 MPa with a zinc coating of Z100 to Z275. For structural sections and plates, Q345B/Q355B material is galvanized as a final step per ISO 1461.

Strength, Corrosion Resistance and Precision in Practice

The three advantages work together. Strength allows thinner sections: compared with a Q235 design, a Q355-based section can be reduced in thickness, and in bending-dominated structures the weight saving is typically 15 to 30 percent, which is the practical meaning of the lighter construction often attributed to Q345. Corrosion resistance comes from the zinc layer: a Z275 hot-dip coating gives decades of protection in atmospheric service, and the zinc layer also protects cut edges by cathodic action. Dimensional precision comes from cold rolling and continuous galvanizing, which hold thickness tolerance and flatness to the tight limits of the product standards, so panels and cabinets assemble without shimming.

Main Application Areas

In the automotive industry, galvanized high-strength sheet is used for door anti-collision beams, chassis cross-members and brackets, where impact strength, snowmelt resistance and formability are all needed. In electrical and appliance equipment it makes distribution box housings, air-conditioner outdoor unit frames and washing machine brackets, profiting from a surface that needs no painting and precise dimensions for assembly. In steel structures and outdoor equipment it appears as purlins, billboard frames and communication base-station brackets, where the zinc layer withstands wind and rain and the higher strength carries the load. Rail transit uses it for interior panels, seat brackets and trackside cabinet housings; agricultural and construction machinery for cab shells, guards and grain tanks exposed to mud and chemicals; and the furniture and kitchen-bathroom sector for wardrobe frames, cabinet brackets and bathroom racks, where the smooth coated surface and ease of drilling and bending matter most.

Processing and Procurement Notes

Galvanized high-strength sheet is cut, bent and punched with the same equipment as mild galvanized sheet, but the higher yield strength means larger bend radii and higher press forces, and the coating must not be allowed to powder at the bend line. When ordering, specify the base strength grade, the coating designation (for example S350GD+Z with Z140), the spangle type, passivation and oiling, and request the EN 10204 type 3.1 certificate so the delivered strength and coating mass are documented.

FAQ

Is Q345 still a current designation?

Q345 was superseded by Q355 when GB/T 1591 was revised in 2018. New orders should specify Q355B; existing drawings calling for Q345B are normally satisfied by Q355B after design confirmation.

What is the difference between Q345 and Q355?

Both guarantee roughly the same yield strength level, 345 MPa versus 355 MPa minimum. Q355 adds tighter composition control and lower carbon equivalent, which improves weldability.

Can Q345/Q355 sheet be supplied galvanized?

Yes. As coil or sheet, high-strength galvanized steel is ordered in structural grades such as S350GD+Z per GB/T 2518 or EN 10346; as plate and sections, Q355B can be hot-dip galvanized per ISO 1461.

What zinc coating is typical for structural galvanized steel?

Coating classes from Z100 to Z275 are common, with Z275 preferred for outdoor structures and coastal service; the number is the total zinc mass in grams per square metre on both sides.

Is galvanized high-strength steel weldable?

Yes. Q355-type steel welds without preheat in most thicknesses, and galvanized sheet welds with the usual precautions for zinc: fume extraction and removal of the coating from the weld zone where porosity matters.

How much weight can be saved versus Q235?

In bending-dominated designs, moving from Q235 to Q355 generally allows section weight savings of roughly 15 to 30 percent, limited by stiffness and deflection requirements rather than strength alone.