Color-coated corrugated board

Sep 09, 2025 Leave a message

1.What is the core composition of color-coated corrugated board?

Substrate layer (core): provides structural strength and supports overall forming; different substrates determine the basic corrosion resistance and mechanical properties of the plate.

Pretreatment layer: clean the substrate surface (remove oil stains and oxide scale), enhance the adhesion between the substrate and the coating, and prevent interlayer shedding.

Coating system: provides decorative properties (color, gloss) and weather resistance (UV resistance, acid rain resistance, and aging resistance), and is the key to "protection + beauty".

Galvanized corrugated sheet

2.What are the core advantages of color-coated corrugated board?

Highly decorative and colorful.
The coating can be customized in a variety of colors (such as iron gray, sea blue, and crimson) and finishes (matte, semi-gloss, and high-gloss), matching various architectural styles (industrial or modern). No post-painting is required, resulting in a beautiful finish immediately after installation, making it particularly suitable for public buildings or factories with demanding appearances.

Excellent weather resistance and low maintenance.
High-quality coatings (such as fluorocarbon and silicone-modified polyester) effectively resist UV aging, acid rain, and high-temperature exposure, making them less susceptible to fading, chalking, and cracking during outdoor use. Compared to galvanized tiles (which are prone to discoloration due to zinc oxidation) or asbestos tiles (which are susceptible to weathering and damage), color-coated tiles offer a longer lifespan (5-20 years, depending on the coating type) and require virtually no maintenance. Lightweight and easy to install.
The panels are typically 0.3-0.8mm thick and weigh only 10-20kg/㎡ (approximately 1/10th the weight of a brick wall), eliminating the need for additional roof reinforcement. Corrugated panels have built-in overlaps after forming, allowing for on-site installation via bolts or snaps, resulting in efficient construction and suitable for quick construction or large-scale roofing projects.

Highly cost-effective and applicable in a wide range of scenarios.
From economical polyester coatings (suitable for temporary structures and warehouses) to high-end fluorocarbon coatings (suitable for permanent structures), flexible options are available to suit your budget and application. They are also waterproof, windproof (standard products can withstand winds up to force 10), and snow-resistant (the corrugated structure distributes the load), making them suitable for both outdoor and indoor applications.

Galvanized corrugated sheet

3.How to judge the quality of color-coated corrugated board?

Coating quality: The key to weather resistance and adhesion.
Appearance inspection: High-quality panels have uniform color, no noticeable color difference, and are free of sag ("tear marks" caused by excessive coating thickness), pinholes (tiny holes), or foreign particles. Touching the surface should make it smooth and flat, without any bumps or graininess (low-quality coatings can easily introduce impurities).
Adhesion test: Use a utility knife to create a "cross" pattern on the surface (1mm square, scratching through the coating to the substrate). Apply 3M tape and quickly remove it. If no coating residue remains, adhesion is acceptable. If the coating flakes off, it may be susceptible to rust later due to rainwater seepage.
Scratch test: Use a hard object (such as a key) to gently scratch the coating surface. High-quality products will only leave a slight scratch, with no primer or substrate exposed. If the paint peels off upon scratching, the coating is insufficiently thick or has poor hardness (prone to damage from transportation and installation friction). Baseboard and Forming Accuracy: Determine Structural Strength.
Baseboard Thickness Measurement: Use a micrometer to measure the flat surface of the sheet (avoiding raised corrugations) to confirm the actual thickness matches the marking (e.g., if marked "0.5mm color-coated sheet," the total thickness of the baseboard + coating should be ≥ 0.48mm to avoid "cutting corners"). If the baseboard is galvanized, refer to the method described in "Cold-Rolled Galvanized Corrugated Sheet" above to check the zinc layer thickness (to ensure basic corrosion resistance).
Corrugated Forming Inspection: Observe the uniformity of the corrugated wave height and wavelength (e.g., common models: 820 type has a 20mm corrugation height, 900 type has a 15mm corrugation height), and observe the absence of "collapsed waves" (localized lower corrugation height) and "warping" (uneven edges). Lay the sheet flat and ensure there is no noticeable warping. Press the raised corrugation area with your hand; it should feel firm and without noticeable springback. (Excessive springback indicates insufficient forming pressure and poor load-bearing capacity.) Weather Resistance Verification (for Outdoor Use)
If used outdoors, ask the supplier to provide weather resistance test reports for the coating (such as UV aging and salt spray resistance tests):
Polyester coating: Salt spray resistance should be ≥500 hours (no visible rust or discoloration);
Fluorocarbon coating: Salt spray resistance should be ≥1000 hours, with a color difference ΔE ≤ 1.5 after UV aging testing (almost no noticeable fading).
Simple judgment: Compare the front and back coatings of the sample. High-quality products have uniform coating thickness on both sides (the back coating is not required to be decorative, but it must provide basic corrosion protection). Low-quality products may only be painted on the front, leaving the substrate exposed on the back (which is prone to rust).

Galvanized corrugated sheet

4.What are the common models and applicable scenarios of color-coated corrugated boards?

Type 820: Roof slope ≥5°, suitable for large-span factories and warehouses (strong load-bearing capacity and good snow resistance).
Type 900: Roof slope ≥3°, suitable for small and medium-sized factories and temporary buildings (high installation efficiency and large coverage area).
Type 760: Roof slope ≥8°, suitable for rainy and snowy areas (high wave height, fast drainage, and strong snow load resistance).
Type 1050: Walls or low-slope roofs

 

5.What are the precautions for purchase and use?

Choose a coating based on your needs: Choose polyester (PE) coating for general industrial buildings; choose fluorocarbon (PVDF) or silicone-modified polyester (SMP) coating for coastal areas, high-temperature and high-humidity areas, or permanent structures. Avoid over-selection (increasing costs) or under-selection (shortening lifespan).

Pay attention to installation details: Allow for expansion joints during installation (to prevent deformation due to temperature fluctuations, as the panels expand and contract). Ensure overlap lengths are ≥ 100mm (to prevent rainwater seepage). Install windproof clips for wall installation (to resist wind loads).

Prevent later damage: Avoid impact with hard objects during transportation (to prevent coating loss). Avoid stacking heavy objects on the panels after installation (to prevent corrugation deformation). Use clean water or a neutral detergent for cleaning (to avoid strong acids or bases corroding the coating).