DC01 and DC06 in the EN 10130 Family
DC01 and DC06 are both cold-rolled low-carbon steel grades defined in EN 10130 for cold forming, with DC06 offering higher formability for extra deep drawing than DC01. For construction-related supply, the quality assurance procedures described here apply equally to both grades: factory inspection, surface quality rules, handling of non-conforming material, flaw detection and certification.
Factory Inspection Items
Before shipment, the mill inspects each batch of cold-rolled coil in five categories:
Chemical composition
Mechanical properties: yield strength, tensile strength and elongation
Dimensional tolerances: thickness, width and shape
Surface quality
Plate shape: flatness and edge condition
Surface Quality Assessment per EN 10130
Under EN 10130, surface defects that affect use, such as cracks, scabs and inclusions, are not permitted. Minor scratches and pitting may be accepted by negotiation between buyer and supplier, depending on the intended application and the agreed surface quality class.
Handling Non-Conforming Mechanical Properties
If the mechanical properties of a batch do not meet the guaranteed values, the agreed handling options are: return of the material to the mill, rework such as re-annealing followed by retesting, or downgrade to a lower grade or to secondary quality by agreement. The final decision is documented in the claim and disposition records.
Flaw Detection and Certification
For general construction and forming applications, no mandatory internal flaw detection is required for DC-type cold-rolled coils. Where the application demands it, such as automotive safety components, ultrasonic or magnetic particle testing can be added by agreement, and any additional testing must be written into the purchase specification.
Each delivery is accompanied by a quality certificate that records the furnace number, batch number, specifications, chemical composition, mechanical properties, surface grade, the applicable standard such as EN 10130, and the inspector signature and date. Buyers should check the certificate against the order before use and keep it for traceability.
FAQ
What items are included in the factory inspection of DC01 and DC06 coils?
Chemical composition, mechanical properties (yield, tensile, elongation), dimensional tolerances, surface quality and plate shape.
How are surface defects of DC01 determined?
According to EN 10130, cracks, scabs and inclusions that affect use are not allowed; minor scratches and pitting can be accepted through negotiation.
What is done if mechanical properties are not compliant?
The material may be returned, reworked, for example by re-annealing, or downgraded according to the agreement.
Is ultrasonic testing mandatory for DC coils?
No; it is not mandatory for general applications. Ultrasonic or magnetic particle testing can be added for special scenarios such as automotive safety components.
What does the quality certificate include?
Furnace number, batch number, specifications, composition, mechanical properties, surface grade, applicable standard, and the inspector signature and date.
Why does DC06 cost more than DC01?
DC06 requires tighter composition control and additional processing to achieve extra deep-drawing properties, which increases production cost.