Hot-Dip Galvanized Steel Coil: Product Overview
Hot-dip galvanized steel sheet in coil, commonly abbreviated GI, is produced by passing cold-rolled full-hard sheet through cleaning and annealing, then through a molten zinc pot so that a metallurgically bonded zinc layer forms on both faces. The result is a material with the strength and plasticity of steel plus a coating that delivers corrosion resistance, paintability and workability at the same time. Sheet and coil are processed to essentially the same specifications, so a buyer can order either form without changing the material call-out.
Because the coating protects cut edges as well as surfaces, galvanized coil is widely used in construction, home appliances and automotive manufacturing, and the combination of substrate choice, coating mass, surface treatment and hardness lets one product family cover a very wide span of forming operations.
Grade Selection: SGCC, SGCH, SGC, SGH, DX51D and SxxxGD
| Grade family | Standard | Character | Typical use |
|---|---|---|---|
| SGCC | JIS G3302 | Commercial quality, good general formability | Panels, ducts, general fabrication |
| SGCH | JIS G3302 | Higher tensile strength than SGCC | Parts needing extra strength at similar gauge |
| SGC340 to SGC570 | JIS G3302 | Structural quality, increasing minimum yield strength | Purlins, decking, load-bearing profiles |
| SGH340 to SGH540 | JIS G3302 | Higher-strength structural quality | Heavy load-bearing sections |
| DX51D to DX54D | EN 10346 | Drawing and deep-drawing qualities, coating expressed as Z | Formed parts, deep drawn housings |
| S220GD to S550GD | EN 10346 | Structural qualities with defined minimum yield strength | Roofing, cladding, structural profiles |
| Q195, Q235 | GB/T | General structural carbon steel substrate | Domestic fabrication and general industry |
The practical rule is straightforward: choose a commercial or drawing grade when forming dominates, and a structural grade when the section carries load. SGCH and the SGH family sit between the two, offering more strength without a full structural specification.
Full Specification Range
| Item | Range |
|---|---|
| Thickness | 0.12-4.0 mm; lighter and heavier gauges subject to review |
| Width | 600-1500 mm as rolled; slit strip from 90 mm |
| Zinc coating | 30-300 g/m2 total, both faces |
| Surface treatment | Chromated, oiled, anti-finger print, or combinations |
| Spangle | Regular, minimized, large or zero spangle |
| Hardness | Soft, half hard and full hard qualities |
| Substrate | Cold-rolled or hot-rolled, depending on grade and thickness |
| Coil inner diameter | 508 mm or 610 mm |
| Coil weight | 3-8 t per coil, or to agreed limits |
| Minimum order quantity | 5 t |
| Standards | JIS G3302, EN 10346, ASTM A653 / A653M, GB/T 2518, AS 1397 |
| Packaging | Export standard, seaworthy |
Thickness, width and coating mass are interlinked: a heavier coating on a thin gauge is harder to keep uniform, and coil inner diameter has to be chosen to suit the customer's uncoiler mandrel. Where a specification sits at the edge of a range, the mill should confirm feasibility against the heat and the line capability before the order is released.
Surface Treatment, Spangle and Hardness
Chromate passivation suppresses white rust in storage and transport and is the default for most shipments.
Oiling adds a further barrier and reduces friction in forming; the oil type is matched to whether the part will be painted.
Anti-finger print treatment is used on coils destined for visible appliance and equipment panels that will be handled before painting.
Spangle is controlled for appearance and paint performance: regular spangle for unpainted structural use, zero spangle where a smooth painted finish is required.
Hardness selection balances formability against strength; soft material draws more easily, while half hard and full hard grades are used for parts that must stay flat and stiff.
Quality Testing and Coil Protection
Production is monitored by experienced quality inspectors who sample products at random during and after rolling, and testing is carried out in an accredited laboratory. Buyers may also designate a third-party inspection body of their choosing to witness and certify the material before shipment.
Coating mass verified per face against the ordered specification
Thickness and width measured across the coil at head, middle and tail
Mechanical properties including tensile strength, yield strength and elongation confirmed on the test certificate
Surface examined for defects, coating skip and passivation streaks
Edge protection fitted before strapping: metal guards or protective pads are placed on the inner and outer rings to prevent edge damage in transit
Frequently Asked Questions
Q: What is the difference between SGCC and SGCH?
Both are JIS G3302 hot-dip galvanized grades. SGCC is commercial quality with good general formability, while SGCH offers higher tensile strength for parts that need more strength at the same thickness.
Q: How do DX51D and SGCC compare?
They play a similar commercial role under different standards. DX51D belongs to EN 10346 and expresses coating mass as a Z designation, while SGCC belongs to JIS G3302 and uses coating codes such as Z08 to Z27.
Q: Which zinc coating range is available?
Coating mass is normally supplied between 30 g/m2 and 300 g/m2 total on both faces, selected according to the corrosivity of the end application.
Q: What thickness range and width can be supplied?
The standard range runs from 0.12 mm to 4.0 mm thick and 600 mm to 1500 mm wide as rolled, with narrower slit strip available from about 90 mm.
Q: What are the minimum order quantity and coil weight?
The minimum order quantity is 5 t, and coils are typically supplied at 3-8 t each, with inner diameters of 508 mm or 610 mm.
Q: How are galvanized coils protected in transit?
Coils are packed to export seaworthy standard, wrapped against moisture, strapped, and fitted with metal guards or protective pads on the inner and outer rings to prevent edge damage.