Cold rolled steel coil, plate, sheet and strip begin as hot rolled coil that is pickled to remove mill scale and then cold reduced between rolls at room temperature. Cold reduction raises strength, tightens thickness tolerance and produces the smooth, uniform surface that visible and painted parts need. The SPCC, SPCD, St12 to St14 and DC01 to DC05 designations in the title all describe this same family of low carbon cold reduced material, named through different national standards.
What Cold Reduction Changes in the Material
Because the strip is worked below its recrystallisation temperature, the grain structure becomes elongated and the sheet gains strength with only a limited loss of ductility. The effects that matter most to a fabricator are:
Thickness tolerance is far tighter than on hot rolled product, often a quarter of the hot rolled range.
The surface is smooth and scale free, so it accepts painting, printing, powder coating and plating directly.
Flatness and camber are controlled closely enough for high speed blanking and roll forming.
After cold reduction the coil is annealed and usually skin passed, which restores formability and avoids stretcher strains.
Yield strength sits around 140 to 280 MPa for the softer drawing grades and higher for the full hard tempers.
SPCC, SPCD, St12 to St14 and the DC Grades Compared
JIS G 3141 names commercial quality SPCC, drawing quality SPCD and deep drawing quality SPCE. The German DIN 1623 designations St12, St13, St14 and St15 were withdrawn and replaced by the EN 10130 grades DC01, DC03, DC04 and DC05 when the European standard was harmonised, so a part once drawn from St13 is now normally satisfied by DC03. The table below sets the common equivalents side by side.
| EN 10130 | Former DIN | JIS G 3141 | Forming duty | Typical yield strength | Elongation A80 |
|---|---|---|---|---|---|
| DC01 | St12 | SPCC | Bending, beading, shallow drawing | 140-280 MPa | 28% min |
| DC03 | St13 | SPCD | Deep drawing and difficult profiling | 140-240 MPa | 34% min |
| DC04 | St14 | SPCE | Complex deep drawing without cracking | 140-210 MPa | 38% min |
| DC05 | St15 | - | Extra deep drawing and severe forming | 140-180 MPa | 40% min |
Buyers who source against several systems at once will also see DC01 written as CR4 in older British literature and as commercial steel in ASTM A1008, while DC04 and DC05 match the deep drawing and extra deep drawing qualities of that same specification.
Chemical Composition Control
Formability in this family comes from very low carbon and tightly limited residuals. Interstitial elements are held down so the annealed sheet stays soft, and phosphorus and sulphur are restricted to avoid cracking in the draw die.
| Grade | Carbon max | Manganese max | Phosphorus max | Sulphur max |
|---|---|---|---|---|
| DC01 | 0.12% | 0.60% | 0.045% | 0.045% |
| DC03 | 0.10% | 0.45% | 0.035% | 0.035% |
| DC04 | 0.08% | 0.40% | 0.030% | 0.030% |
| DC05 | 0.06% | 0.35% | 0.025% | 0.025% |
Dimensions, Surface and Delivery Form
Thickness normally runs from 0.2 mm to 3.0 mm, with the thinnest gauges supplied as precision strip.
Coil widths range from narrow slitted strip up to about 1500 mm, and cut lengths are available as sheet or plate.
Surface qualities are offered as matte, normal and bright finish, with bright reserved for exposed parts.
Oiling, dry protection and edge trimming are chosen according to storage time and the forming process that follows.
Coil, oscillated coil, cut to length sheet, slit strip and blanked plate all come from the same heat.
Typical Applications
Domestic appliances, cabinets and shelving formed from DC01 and SPCC sheet.
Automotive interior panels, brackets and seat frames in DC03 and DC04.
Complex drawn parts such as oil pans, housings and deep shells in DC04 and DC05.
Roll formed sections, racking columns, door frames and furniture tube.
Base metal for later galvanizing, colour coating or vitreous enamelling.
Frequently Asked Questions
Q: Is DC01 the same as St12?
Yes. St12 was the DIN 1623 designation for the basic cold forming grade, and EN 10130 replaced it with DC01. The mechanical requirements are equivalent for ordinary commercial forming work.
Q: What is the difference between DC01 and DC03?
DC01 suits simple forming such as bending, embossing, beading and shallow drawing, while DC03 offers the higher elongation and lower yield strength needed for deep drawing and difficult profiling.
Q: Which grade should be used for a complex deep drawn part?
DC04 handles complex shaping and deep drawing without cracking, and DC05 is specified when the draw is more severe again. DC01 is not suitable for these operations.
Q: How does SPCC differ from SPCD?
Both come from JIS G 3141. SPCC is the commercial quality grade, while SPCD is the drawing quality grade with a higher elongation requirement for parts that must be formed more deeply.
Q: Can cold rolled sheet be supplied already oiled?
Yes. Coils and sheets are supplied dry, lightly oiled or with a heavier protective film, and the choice depends on storage time and the painting or forming process that follows.
Q: Is cold rolled strip available in narrow widths?
Coil can be slit to narrow strip with deburred or trimmed edges, which allows direct feeding into roll forming and press lines without further preparation.