The grade list SPCC, JSC270C, DC01, BLC, DC03, BLD, DC04, DC05 and St12 mixes four naming systems in a single line, which is common on export enquiry sheets but confusing when the material is finally ordered. This guide separates the designations, maps the equivalents, and then shows how those choices feed into galvanized corrugated roofing plate and the price that follows.
What Each Designation Actually Means
SPCC, SPCD and SPCE are the commercial, drawing and deep drawing qualities of JIS G 3141 for cold reduced sheet.
DC01 to DC05 are EN 10130 grades, while St12, St13 and St14 are the older DIN 1623 designations that they replaced.
BLC, BLD, BUSD and BUFD are the commercial, drawing, deep drawing and extra deep drawing grades of GB/T 5213 for continuously annealed cold rolled sheet.
JSC270C belongs to the hot dip galvanized corrugated sheet family of JIS G 3302, where the number indicates a minimum tensile strength of 270 MPa for the corrugated product.
Cross Standard Equivalents
The table below is the working comparison used when a drawing specifies one system and the mill stocks another. Differences in annealing practice mean the grades are equivalent in forming duty rather than identical in every measured value.
| Forming duty | EN 10130 | DIN 1623 | JIS G 3141 | GB/T 5213 | ASTM A1008 |
|---|---|---|---|---|---|
| Commercial quality | DC01 | St12 | SPCC | BLC | CS Type B |
| Drawing quality | DC03 | St13 | SPCD | BLD | DS |
| Deep drawing quality | DC04 | St14 | SPCE | BUSD | DDS |
| Extra deep drawing | DC05 | St15 | - | BUFD | EDDS |
In older British literature DC01 also appears as CR4, and the same grade is sold as commercial steel under ASTM A1008. When a roofing profile is roll formed from coil, the drawing quality grades are usually unnecessary: commercial quality with a sound galvanized coating performs better because the extra softness of the deep drawing grades can mark during forming.
Galvanized Corrugated Roofing Plate
Corrugated galvanized roofing plate starts as a hot dip galvanized coil that is roll formed into a wave or trapezoidal profile and cut to length. The base sheet is hot dip galvanized on a continuous line, so the coating is metallurgically bonded to the steel and follows the profile without flaking at the bends. Typical delivery data are set out below.
| Item | Range or option |
|---|---|
| Profile type | Wave corrugated, trapezoidal, ribbed |
| Base steel grade | SPCC, SGCC, JSC270C, DX51D+Z, or an agreed equivalent |
| Base thickness | 0.14 mm to 1.2 mm before profiling |
| Effective width | 600 mm to 1070 mm depending on profile |
| Zinc coating | Z180, Z275 or Z350, chromated or non chromated, oiled or dry |
| Length | Cut to order, normally up to 6 m per sheet |
The coating mass, not the profile, is the main determinant of service life. A Z275 coating supplies roughly 275 g/m2 of zinc across both faces, which is about 19 micrometres per side and matches the G90 designation of ASTM A653.
Zinc Coating Designations Across Standards
| EN 10346 | ASTM A653 | JIS G 3302 | Total coating mass |
|---|---|---|---|
| Z180 | G60 | Z18 | 180 g/m2 |
| Z275 | G90 | Z27 | 275 g/m2 |
| Z350 | G115 | Z35 | 350 g/m2 |
Coating designation is quoted as the total mass on both surfaces, so a Z275 sheet carries about 137 g/m2 on each face. Roofing projects in humid or coastal areas normally specify Z275 as a minimum, while an inland covered application can use Z180 and still reach a long service life.
What Drives the Delivered Sheet Price
Substrate grade: a drawing quality annealed substrate costs more than commercial quality, and high strength grades cost more again.
Zinc coating mass: coating metal is a large share of the cost, so Z275 sits above Z180 for the same thickness.
Thickness and width: thinner gauges and non standard widths raise the per tonne price through extra rolling and slitting.
Surface treatment: chromate passivation, oiling and anti fingerprint films add processing steps.
Order form: full coils are cheaper per tonne than slit strip, cut lengths or profiled sheets.
Quantity and delivery: small lots lose the benefit of a full production run, and short lead times attract a premium.
Frequently Asked Questions
Q: Is JSC270C the same as SPCC?
No. JSC270C is a galvanized corrugated sheet grade from JIS G 3302 with a stated minimum tensile strength, while SPCC is an uncoated cold reduced commercial quality grade from JIS G 3141.
Q: Can BLD replace DC03?
They cover the same drawing duty. BLD comes from GB/T 5213 and DC03 from EN 10130, so either can be substituted if the supplier confirms the measured elongation and yield strength.
Q: Does a higher zinc coating always mean a longer life?
Coating mass is the largest single factor, but cut edges, fastening points and forming damage also control first corrosion, so the profile design and site handling matter as much as the coating figure.
Q: What does CR4 mean on a drawing?
CR4 is an older British designation for the basic cold reduced drawing grade, equivalent in practice to DC01. It should not be confused with the deep drawing grades, which offer higher elongation.
Q: Why is corrugated roofing supplied in widths below the coil width?
Profiling consumes width as the flat sheet is formed into waves, so the effective cover width is always smaller than the base coil width used to produce it.
Q: Which coating is suitable for coastal roofing?
Coastal atmospheres carry chlorides that attack zinc quickly, so Z275 or Z350 with a chromate passivation and a coated finish on both faces is the normal starting point.