DX51D DC01 G90 Z275 Cold Rolled Zinc Coated GI Steel Sheet in Coil 0.2 mm 0.3 mm

Sep 08, 2025 Leave a message

Thin galvanized coil is usually specified with two things in one line: a cold-rolled substrate grade such as DX51D or DC01, and a zinc coating mass such as G90 or Z275, followed by the required thickness. Reading that combination correctly is what prevents a light-gauge order from arriving with the wrong coating or the wrong forming behaviour.

What DC01 Means and What It Is Equivalent To

DC01 is a non-alloy cold-rolled steel for cold forming, defined in EN 10130 under material number 1.0330. Its very low carbon content makes it soft, ductile and easy to work, which is why it is chosen for bending, beading, embossing and light drawing rather than for structural duty. The nearest designations in other systems are the JIS G3141 commercial quality grade SPCC, the historic German grade St12 from DIN 1623, and ASTM A366 for cold-rolled commercial quality sheet.

DC01 - Re 140–280 MPa, Rm 270–410 MPa, A80 minimum 28 %.

DC03 - Re 120–240 MPa, Rm 270–370 MPa, A80 minimum 34 %, for deep drawing.

DC04 - Re 110–210 MPa, Rm 270–350 MPa, A80 minimum 38 %, for the most demanding forming.

The older St12 name was superseded when DIN 1623 was withdrawn in favour of DIN EN 10130, so a drawing that still shows St12 should be read as DC01 unless a tighter grade was intended.

G90 and Z275: The Same Coating Under Two Systems

Z275 is an EN 10346 coating class stating 275 g/m² of zinc measured over both surfaces. G90 comes from ASTM A653 and states 0.90 oz/ft² over both surfaces. Because 1 oz/ft² equals about 305 g/m², the two designations describe the same nominal coating, which is why galvanized sheet can be quoted either way without any change to the product.

Designation Standard Total coating mass Approx. zinc per side
Z100 EN 10346 100 g/m² ≈ 7.0 µm
G60 ASTM A653 ≈ 183 g/m² ≈ 12.8 µm
Z225 EN 10346 225 g/m² ≈ 15.8 µm
G90 / Z275 ASTM A653 / EN 10346 275 g/m² ≈ 19.3 µm
Z350 EN 10346 350 g/m² ≈ 24.5 µm

Coating mass is always quoted as the total over both surfaces. The per-side figure is derived by halving the mass and dividing by the density of zinc, about 7.14 g/cm³, which is why Z275 is often described as roughly 19 µm per side.

Light Gauge Coil in 0.2 mm and 0.3 mm

Coils at 0.2 mm and 0.3 mm sit at the lower end of the normal production range. DX51D+Z and DC01 based galvanized material are routinely rolled from 0.20 mm upward, and these gauges are used for cable trays, ducting, light appliance panels, ventilation housings and thin cladding profiles.

Thickness range - 0.20–3.00 mm, with tolerance to EN 10131 or ASTM A924.

Width - 600–1500 mm in coil, or slit to narrower strip.

Coil - inner diameter 508 mm or 610 mm, weight typically 3–10 t.

Surface - regular spangle, minimised spangle or skin-passed, with roughness Ra 0.8–1.8 µm.

Protection - light oil film or anti-finger treatment to limit white rust in transit.

Forming Behaviour of Very Thin Galvanized Sheet

At 0.2 mm and 0.3 mm the forming window narrows quickly. Springback rises, edge cracking becomes more likely, and tooling radii that work at 1.0 mm will not perform the same way. A practical rule is to keep the bending radius at three times the sheet thickness or more, and to specify an oiled surface so that friction in the die stays low and the zinc layer is not scored. Where a part needs a sharp corner or a heavy draw, DC03 or DC04 substrate gives noticeably more elongation than DC01 at the same coating mass.

Inspection, Storage and Handling

Galvanized coil should be supplied with a mill test certificate to EN 10204 3.1 recording the heat analysis and the mechanical results, and with coating mass verified by the triple-spot weighing method of EN 10346 or ASTM A653. Adhesion is checked by T-bend and impact test, hardness and paint compatibility by pencil test where the coil will later be painted, and corrosion resistance by neutral salt spray to ASTM B117 or ISO 9227.

On site, coil should be stored indoors on dry timber or plastic dunnage, kept clear of condensation and stacked so that water cannot collect between laps. White rust and wet-stack staining form within days in humid conditions and are far easier to prevent than to remove.

Frequently Asked Questions

Q: What is DC01 material equivalent to?
DC01 corresponds to material number 1.0330 in EN 10130, to SPCC in JIS G3141, to the historic St12 grade of DIN 1623, and broadly to ASTM A366 commercial quality cold-rolled sheet.

Q: Is DC01 the same as CR4?
CR4 is an older British trade label for cold-reduced mild steel of comparable quality. In current practice DC01 is the governing designation because it carries the guaranteed mechanical properties.

Q: Are G90 and Z275 identical?
For practical purposes yes. G90 means 0.90 oz/ft² over both surfaces and Z275 means 275 g/m² over both surfaces, and the two convert to the same nominal coating mass.

Q: Is 0.2 mm galvanized coil a standard product?
Yes, 0.2 mm and 0.3 mm are normal light-gauge sizes, though the tolerance band is proportionally wider than on heavier gauges and the forming radius must be increased.

Q: What does the Z in Z275 stand for?
The Z indicates a zinc coating applied by continuous hot dipping, and the number that follows is the total coating mass in grams per square metre over both surfaces.

Q: Why does galvanized coil turn white in storage?
White rust is zinc hydroxide and zinc oxide formed when moisture sits on the surface without free air circulation. Dry, ventilated indoor storage and a light oil film greatly reduce the risk.