Hot-dip galvanized steel coil is strip steel coated with zinc in a continuous line. The process starts with cleaning and pickling to remove oil and scale, followed by fluxing with ammonium chloride and zinc chloride, then immersion in a molten zinc bath at roughly 450-470 °C. Gas knives wipe the strip to the target coating weight, the zinc solidifies into a spangle pattern, and the strip is cooled, skin-passed, and finally passivated or oiled to prevent white rust in storage. The result is a zinc layer metallurgically bonded to the steel, so it does not flake under bending and continues to protect the steel sacrificially at scratches and cut edges.
Grade families: SGCC, SGCD and SGHC
Under JIS G3302, SGCC is the commercial-quality grade based on a cold-rolled substrate; it is the default choice for general forming, roofing and ducting, and no tensile value is guaranteed on the certificate. SGCD is the drawing-quality grade with better formability for pressed components. SGHC is the structural family based on a hot-rolled substrate, with grades SGH340 to SGH570 guaranteeing minimum tensile strengths from 340 to 570 N/mm²; SGHC is used where the panel must carry load. In European practice the same products are covered by EN 10346: DX51D to DX54D for forming, and S220GD to S550GD for structural use.
| Grade | Standard | Base | Key property | Typical use |
|---|---|---|---|---|
| SGCC | JIS G3302 | cold rolled | commercial, no tensile guarantee | ducting, housings, general sheet |
| SGCD | JIS G3302 | cold rolled | drawing quality | pressed and drawn parts |
| SGHC | JIS G3302 | hot rolled | SGH340-SGH570, tensile 340-570 N/mm² min | purlins, frames, load-bearing profiles |
| DX51D | EN 10346 | cold or hot rolled | Rp0.2 140-300 MPa, Rm 270-500 MPa, A80 22% min | roll forming, bending, moderate drawing |
| S350GD | EN 10346 | cold or hot rolled | Rp0.2 350-500 MPa, Rm 420-600 MPa, A80 16% min | structural sections, solar frames |
| S550GD | EN 10346 | cold or hot rolled | Rp0.2 550-700 MPa, Rm 560-700 MPa, A80 8% min | high-strength profiles, cold-formed sections |
Coating classes and surface finishes
Coating mass is written as Z followed by grams per square metre on both surfaces, from light classes such as Z30 and Z40 up to Z275 and beyond. Light coatings below Z80 are used indoors or where the panel is painted afterwards; Z180 to Z275 suit outdoor structures, fencing and agricultural buildings. Surface finish options include regular spangle, minimised spangle and spangle-free, plus a zinc-iron alloy finish for welding and painting. For shipment, chromate-free passivation or light oiling is applied to delay white rust; coils are normally wrapped with moisture-barrier paper and edge protection.
Dimensional range and tolerances
Typical supply covers thickness from 0.12 mm to 4.0 mm and width from 600 mm to 1500 mm, with coil weights of 3-8 tonnes. Tolerances on thickness, width, camber and flatness follow EN 10143 for European orders or the corresponding clauses of JIS G3302 for Japanese-spec orders; the buyer should state the tolerance standard in the contract because slitting and shearing to custom sizes changes the permissible values.
Six practical advantages of the product
First, galvanized coil is a low-cost corrosion solution compared with painting or stainless steel over a 20-50 year design life. Second, the coating is durable and self-healing at scratches through sacrificial action. Third, the zinc-steel metallurgical bond survives bending, profiling and moderate forming. Fourth, the steel base keeps its toughness, so the product can be punched, riveted and welded without special treatment in most indoor uses. Fifth, coverage is complete on both faces and edges formed in the line, unlike field-applied paint. Sixth, installation is fast because panels arrive ready to use, saving labour and finishing time.
How to select the right coil for a project
Start from the environment: dry interior points to SGCC or DX51D with Z80-Z140; exterior exposure points to Z180-Z275 or an AZ coating; heavy load points to SGHC, S350GD or higher structural grades. Then fix the forming route: roll forming tolerates SGCC and DX51D, deep drawing needs SGCD or DX53D, welding-heavy fabrication prefers minimised spangle or zinc-iron alloy. Finally set the surface class and passivation, and require a mill certificate with standard numbers, coating mass and mechanical values before accepting the consignment.
Frequently asked questions
What is the difference between SGCC and SGHC?
SGCC is a commercial-quality cold-rolled-based grade without guaranteed tensile values, while SGHC is a structural family on hot-rolled base with guaranteed minimum tensile strengths of 340-570 N/mm² for load-bearing parts.
What does Z30 or Z40 mean?
Z30 means a total zinc coating mass of 30 g/m² on both surfaces, and Z40 means 40 g/m²; these light classes are used for indoor painted or mildly exposed parts and are not intended for long outdoor service.
Can SGCC coils be bent 180 degrees without coating cracks?
Bending performance depends on coating mass and bend radius; light coatings and larger radii survive 180-degree bends, while heavy coatings such as Z275 may show cracking at tight radii, so specify a bend test when the application demands it.
Why does the certificate show no tensile value for SGCC?
JIS G3302 classifies SGCC as commercial quality and does not require mechanical guarantees; the certificate records coating mass and surface checks, while tensile values are only stated for drawing and structural grades.
Is Z275 equal to G90 in ASTM terms?
Practically yes: Z275 in EN 10346 equals 275 g/m² total on both surfaces, and G90 in ASTM A653 equals 0.90 oz/ft², which converts to the same 275 g/m² total.
How should coils be stored on site?
Keep them dry and off the ground, tilt to drain any condensation, avoid direct contact with rainwater and dissimilar metals, and use the stock first-in-first-out; white rust can form quickly if wrapped coils are stored outdoors without a cover.