Transformer Oil Leakage Problem

Mar 05, 2024 Leave a message

With the development of the power industry, how to improve the performance of power equipment and ensure the reliable operation of the power system is an urgent problem that needs to be solved in power production. Therefore, whether the problem of oil leakage in transformers can be dealt with in a timely and thorough manner has gradually become a Important technical indicators for measuring the development of the electric power industry. Oil leakage from oil-immersed power transformers is common in power systems. If there is oil leakage from a transformer, it may affect the safe and stable operation of the transformer. How to solve the problem of oil leakage from transformers has been a major problem in the production practice of the power sector for many years.

voltage transformer

 

1. Analysis of the causes of oil leakage from transformers

 

According to operating experience, oil leakage from transformers generally occurs in the following seven main parts: ① The connection surface of the main body cover; ② The radiator; ③ Sampling valve; ④ Bushing; ⑤ The oil pipe flange surface; ⑥ The transformer base interface; ⑦ Gas Relays etc. It can be found that most of the leakage points are flange joint surfaces, seals and valves. Unreasonable flange structure, poor seal material quality, poor processing technology, changes in external ambient temperature, pressure, etc. will all cause leakage of the transformer. These factors complement each other and influence each other. When there is a problem in one of the links, it will cause a chain reaction and lead to oil leakage. In practice, the following specific analyzes were carried out:

10kva transformer

First, the manufacturing process of the flange surface is unreasonable, and the leakage points at the oil drain plug of the transformer radiator interface account for more than half of the total leakage points. The reasons for leakage are: (1) There are rust, burrs, grooves, etc. on the contact surface; (2) There are no sealing grooves and unlimited pins; (3) There is paint and other dirt on the contact surface; when handling paint debris Sometimes, scars may be scratched on the sealing surface; (4) The position and tightness of the sealing rubber ring are determined entirely by experience. Too loose or too tight may cause leakage.

 

Second, the most commonly used sealing material is nitrile rubber. The sealing rings and gaskets made of it have poor oil resistance and age quickly. Especially at high temperatures, they can easily cause aging cracks and loss of elasticity. In addition, due to the uneven smoothness of the sealing surface during the installation process, the amount of compression increases and leads to leakage.

The third is the manufacturing process and material quality of the transformer casing. If the transformer casing has pores, blisters, false welding, and desoldering, it will cause oil leakage from the transformer.

 

Fourth, the connection surface of the plate butterfly valve is relatively rough and thin, with only a single layer of sealing, causing leakage in the transformer.

 

The fifth is the influence of temperature. When the outside temperature is low and the transformer is not installed in the summer, after operation in the summer (the temperature is as high as 37°C), the seals that are tightly compressed during installation increase the amount of compression due to the thermal expansion of the metal, and when the temperature drops in winter ( The lowest temperature can reach -4℃), the elasticity of the seal is reduced, and the compression is reduced, causing leakage to occur from time to time.

 

2. Analysis of types of transformer oil leakage

1. Air leakage. It is an invisible leak. Such as the leakage of air in and out of the casing head, the diaphragm of the oil conservator, the glass of the safety airway, and the weld blisters. Moisture and oxygen in the air will slowly penetrate into the body through the leaked parts, and the seal between the inside and the outside of the transformer will be destroyed, causing problems such as moisture in the insulation and accelerated aging of the oil.

 

2. Oil leakage. One is internal leakage. The oil in the bushing or the oil in the on-load tap changer chamber leaks into the transformer body. The second is external leakage. Weld leakage and seal leakage are the most common leakage phenomena.

 

3. Analysis of prevention and control strategies for transformer oil leakage

Through long-term practice and exploration, some practical methods and measures for dealing with transformer oil leakage have been found.

 

1. Treatment of sealing surface. In the case of rust, burrs, and grooves on the flange sealing surface, measures such as strengthening rust removal, repair welding, and grinding are adopted to improve the smoothness of the flange surface and make it meet the requirements. Before installing the seal, wipe the flange surface with a clean cloth to ensure that there are no oil stains, metal powder and other impurities on the flange surface that can easily form oil and gas channels. Corresponding limit grooves and limit pins are processed on the flange surface to effectively prevent the seal from sliding and excessive compression, effectively reducing the aging speed of the seal and reducing the occurrence of leakage.

 

2. Use a new type of polymer material with good high temperature resistance and oil resistance - polytetrafluoroethylene body seal. The molecular structure of this material is more compact than that of Buna N rubber, and it can withstand greater pressure and shear force, and better solves the problem of oil leakage caused by the aging of seals.

 

3. Upper part of casing 6~10 kV The main reasons for oil leakage in the upper part of casing are small compression of the sealing gasket, failure to tighten the handshake clamp and heat damage to the sealing gasket. The solution is: replace the sealing gasket or tighten the conductive rod compression nut and upper clamp. If the handshake wire clamp is not tight, the slot of the clamp should be milled larger.

4. Blisters and oil leakage at welds. Judging from the actual situation on site, blisters and weld leakage rates are the highest. The reasons are caused by improper craftsmanship, lax leak testing or material problems during the casting and welding processes. The treatment method is: if the blisters are not large and the amount of oil leakage is small, the leak can be plugged with electricity. That is, wipe the leaked oil area clean, block the oil leak hole with soap, and then apply LD-1 type quick-acting leak sealant. After solidification It can solve the problem of oil leakage from trachoma, and the effect is very good.

 

When dealing with oil leakage from welding seams, first use a saw blade to clean off the paint, oxide layer, etc. in the leaking area to expose its true color, then wipe it clean with alcohol cleaner, seal the welding seam with sealant, and then solidify to block the leakage. Oil leak. If the leakage area is too smooth, the surface can be polished to increase the adhesion. For those that require repair welding during a power outage, carbon dioxide shielded welding and automatic arc welding should be promoted. After repair welding, the relevant leak test methods should be carefully implemented. and leak detection standards.

 

5. Oil leaks from the sealing area of the vent (oil) bolt. This is often caused by the use of improperly designed bolts. When the pressure is small, the sealing gasket will not be compressed enough and leak; when the pressure is too high, the gasket will exceed the elastic limit and leak. The solution is to modify the bolt structure, that is, to create a circular sealing groove on the bolt cap with a depth of about 3 mm. This can press the gasket into the groove, limiting the outward expansion of the gasket under extrusion to maintain good elasticity of the gasket.

 

6. Oil leakage occurred in many places at the welding parts of the heat sink of a main transformer at a certain station. Although the manufacturer welded it several times, it was not completely cured. After many tests, modified acrylate adhesive was used to treat the leakage points without power outage, and achieved good results. The specific methods are now introduced as follows:

(1) Benefits of using modified acrylic adhesive to treat leaks. Using modified acrylic adhesive to deal with leakage problems in oil injection equipment is simple and convenient to operate, easy to learn and master. It avoids the danger of transformer oil burning caused by high-temperature welding, avoids the possibility of carbonization of transformer oil caused by high temperature, and can handle without power outage, ensuring continuous and reliable power supply.

 

(2) Key points in using modified acrylic adhesive to treat leaks. First, clean the leaked oil with dish soap or washing powder. After drying, use coarse emery cloth to remove the paint on the leakage area. Then use fine emery cloth to further polish the leakage area to make it flat, smooth, clean and stain-free. . If the leakage lasts for a long time and there is a lot of sludge deposited, you can first use a blade to remove the sludge, then clean it with dish soap, dry it with a cloth, and polish it with sandpaper.

 

If serious oil leakage is found after cleaning (more than 10 drops of oil per minute), you can mix the modified acrylate adhesive thoroughly and apply it directly to the gap. Stop the oil leakage first, and then use a tool to smooth the applied glue. Then clean and polish. This stage is called priming. After the priming is completed, evenly apply the modified acrylic adhesive on the priming surface. Wait for 1 minute and when it is no longer sticky, squeeze the adhesive evenly with your hands to allow the glue to effectively enter the gaps and block oil leakage points. After treatment, observe for a month. If there are no more oil stains on the leakage area, spray anti-rust paint.

 

7. Choose transformers with good performance, high quality and advanced technology. Replace seals regularly. Even if the seal has not exceeded its service life, it should be replaced before aging failure occurs to avoid deterioration of leakage.

 

8. Good personnel quality is one of the keys to solving leakage. For the same transformer, if the installation and maintenance personnel are different, the results will be completely different. The quality of the installation and maintenance team is an important factor in reducing transformer leakage.

 

In recent years, we have taken a series of measures to prevent oil leakage, which has greatly reduced the oil leakage rate after transformer overhaul. Practice has proved that as long as careful inspection and analysis are carried out and the quality of installation and maintenance is paid attention to, the problem of oil leakage in the transformer can be completely solved, thus improving the safety and reliability of the transformer operation. Only by continuously improving and summarizing prevention and control measures can the oil leakage rate of transformers be greatly reduced, which can provide guarantee for the safe operation of transformers and achieve economic benefits for enterprises, society and users.